1244

Table 1. SYMAPI_AEVENT2_UID_ALERT_ARR_COMP_STATUS
1244 SYMAPI_AEVENT2_UID_ALERT_ARR_COMP_STATUS
Category status
Component
  • Power=xxx
  • Fan=xxx
  • LCC=xxx
  • Enclosure=xxx
  • MM=xxx
  • IOMC=xxx
  • Dir=xxx
Severity
  • If Online: Normal
  • If Online Degraded: Warning
  • If Offline: Major
  • If Unknown: Warning
Message Component state has changed to [Not Present | Unknown | Online | Write Disabled | Offline | Failed]
Table 2. Unisphere policy name
Unisphere policy name Array Component Events
Action type Alert
  • Online — means that the component is a Normal or Degraded state.
  • Online [Degraded] — means that the component is in a degraded state.
  • Offline — means that the component is in a Failed state.

The format of the specific component name (xxx above) may differ depending on the VMAX model. Some examples you might encounter are:

Table 3. Components
Component Description
SB-1/Fan-A Fan in System Bay
SB-1/ENC-1 Enclosure within System Bay
SB-1/ENC-1/Fan-A Fan in Enclosure-Slot within System Bay
SB-1/MIBE-L-2A MIBE within System Bay
SB-1/MIBE-L-2A/PS-A Power Supply in MIBE within System Bay

Notes

Indicates a change in environmental status for one of the following types of sub-components within the VMAX array:

Table 4. Types of subcomponents
Sub-component Type
Fans: [ Fan ]
Power Supplies: [ Power ]
Link Control Cards: [ LCC ]
Management Modules [ MM ]
IO Module Carriers [ IOMC ]
Directors (for environmental alerts): [ Dir ]
Enclosures or Matrix Interface Board Enclosures [ Enclosure ]